design group parameter value
SEmax 1 E0 1.47408567497757
SEmax 1 Emax 15.0929142182343
SEmax 1 ED50 169.200410297359
SEmax 2 E0 1.46979455295123
SEmax 2 Emax 18.1160170145552
SEmax 2 ED50 178.003462949654
SEmax 3 E0 0.567622637787943
SEmax 3 Emax 22.0018527350886
SEmax 3 ED50 202.389935630116
SEmax 4 E0 1.07017190587751
SEmax 4 Emax 22.4087472973006
SEmax 4 ED50 223.886054744955
SEmax 5 E0 1.46383719275201
SEmax 5 Emax 22.428961949724
SEmax 5 ED50 250.608087724541
SHill 1 E0 1.52750745944683
SHill 1 Emax 6.13920417578685
SHill 1 ED50 176.25410186255
SHill 2 E0 1.52932326033022
SHill 2 Emax 12.3512929080443
SHill 2 ED50 299.193675742403
SHill 3 E0 0.884295752913902
SHill 3 Emax 23.1756555647046
SHill 3 ED50 343.456185833615
SHill 4 E0 1.45406169666083
SHill 4 Emax 23.5689450448635
SHill 4 ED50 354.559318867084
SHill 5 E0 1.56157765378903
SHill 5 Emax 23.2938057924746
SHill 5 ED50 351.299670393309